| Home | E-Submission | Sitemap | Contact Us |  
top_img

The Korean text of this paper can be translated into multiple languages on the website of http://jksee.or.kr through Google Translator.

J Korean Soc Environ Eng > Volume 37(8); 2015 > Article
J Korean Soc Environ Eng 2015;37(8): 480-491. doi: https://doi.org/10.4491/KSEE.2015.37.8.480
새만금 비점오염원 관리지역에서의 목표설정 및 달성도 평가방법론 연구
김은정1, 박배경1, 김용석1, 류덕희1, 정광욱2
1국립환경과학원 유역총량연구과
2(사)한국수계환경연구소
A Study on Development of Management Targets and Evaluation of Target Achievement for Non-point Source Pollution Management in Saemangeum Watershed
Eun-Jung Kim1, Bae-Kyung Park1, Yong-Seok Kim1, Doug-Hee Rhew1, Kwang-Wook Jung2
1Watershed and Total Load Management Researech Division, National Institute of Environmental Research
2Korea Water Environment Research Institute
Corresponding author  Bae-Kyung Park ,Tel: 032-560-7403 , Fax: 032-568-2044, Email: bkpark67@korea.kr
Received: June 26, 2015;  Revised: August 28, 2015;  Accepted: August 30, 2015.  Published online: August 31, 2015.
ABSTRACT
In this study, methods using LDC (Load Duration Curve) and watershed model were suggested to develope management targets and evaluate target achievement for non-point source pollution management considering watershed and runoff characteristics and possibility for achievement of target. These methods were applied for Saemangeum watershed which was designated as non- point source pollution management area recently. Flow duration interval of 5 to 40% was selected as flow range for management considering runoff characteristics and TP was selected as indicator for management. Management targets were developed based on scenarios for non-point source pollutant reduction of management priority areas using LDC method and HSPF model which was calibrated using 4 years data (2009~2012). In the scenario of LID, road sweeping and 50% reduction in CSOs and untreated sewage at Jeonju A20 and 30% reduction in fertilizer and 50% in livestock NPS at Mankyung C03, Dongjin A14 and KobuA14, management targets for Mangyung bridge, Dongjin bridge, Jeonju stream and Gunpo bridge were developed as TP 0.38, 0.18, 0.64 and 0.16 mg/L respectively. When TP loads at the target stations were assumed to have been reduced by a certain percentage (10%), management targets for those target stations were developed as TP 0.35, 0.17, 0.60 and 0.15 mg/L respectively. The result of this study is expected to be used as reference material for management master plan, implementation plan and implementation assessment for non-point source management area.
Key Words: Management Target, LDC (Load Duration Curve), Non-point Source Pollution Management, Saemangeum, Watershed Model
Editorial Office
464 Cheongpa-ro, #726, Jung-gu, Seoul 04510, Republic of Korea
TEL : +82-2-383-9653   FAX : +82-2-383-9654   E-mail : ksee@kosenv.or.kr
About |  Browse Articles |  Current Issue |  For Authors and Reviewers
Copyright © Korean Society of Environmental Engineers.                 Developed in M2PI